54
Rev G
Operational Values Description
Accuracy Display and relays: 0.01 percent +/- 1digit
Analog: .1% linearity
Frequency range .01 Hz to 4Khz
Response Time Minimum 0.02 seconds
Control Range
Default 500
1, can be programmed from 9999
1
Modes of Operation
•
Speed
•
Time in process
•
Single channel
•
Quadrature
Set Points
•
2 or 6 programmable as “over” or “under”
•
Forward and reverse
Display Update Time
0.5 seconds update time minimum; 8 seconds update time maximum
Mechanical Description
Enclosure
ABS Plastic 94V
0
Keypad Polycarbonate Tactile switch pad, chemical resistant, splash proof
Display 4 digit .3 inch height, seven-segment display, 5 status LEDs
Operating Temperature 0º C to 50º C (+32º to + 122º F)
Humidity 0% to 90% non-condensing
Specifications are subject to change without notice.