EasyManua.ls Logo

Electrolux DIVA 60 - Table of Regeneration Values; Drying; Turbo-Dry Drying

Electrolux DIVA 60
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SOI/DT 2003 - 01 eb 25 599 35 63-72
6.14.3 Table of regeneration values
Water introduced
between
regeneration
cycles
Aperture of
regeneration
solenoid
Position of
selector in
the tub
Hardness of the
water
Level Display
litres sec º F (TH) º D (dH)
1
1L - - - 0 1 0 > 8 0 > 4
2
2 L 130 240 1 9 > 14 5 > 8
3
3 L 94 240 1 15 > 20 9 > 11
4
4 L 70 240 1 21 > 30 12 > 17
* 5
5 L 53 240 2 31 > 40 18 > 22
6
6 L 37 240 2 41 > 50 23 > 28
7
7 L 20 240 2 51 > 60 29 > 33
8
8 L 15 240 2 61 > 70 34 > 39
9
9 L 10 240 2 71 > 80 40 > 45
10
10 L 3 2x240 2 81 > 90 46 > 50
* “5” = factory-set level Position of selector in tub: “2”
7 Drying
ACTIV-DRY TURBO-DRY
In these dishwashers, the dishes
are dried by means of a steam
condensation process. The drying
system is based on the circulation
of the hot air produced during the
hot rinse, in which the steam
circulates inside the condenser of
the fill tank.
The condenser is a condensation
chamber filled with water (cold
wall); contact between the hot air
and the cold wall results in the
condensation process.
Depending on the type of
appliance, one of two drying
systems is used:
- "ACTIVE - DRY" drying
- "TURBO - DRY" drying.
7.1.1 “Turbo-dry” drying
Certain models feature a forced-air drying
system.
The steam is drawn in by the fan located inside
the upper duct and routed towards the condenser
in the fill tank, from which it returns to the tub
through the steam venting ring.
The fan motor (MV) is powered by triac TY6
(connector D3 on the circuit board) and by the
contacts of the ON/OFF switch (PU) and the door
switch (IP).
The drying time is variable and pre-defined for
each washing cycle.
In some programmes, the fan remains in
operation for about 20 minutes after the end of
the cycle; if the door is opened, the fan switches
off.

Table of Contents

Related product manuals