SOI/DT 2003 -01 eb 37 599 35 63-72
12 QUICK GUIDE TO THE SPECIAL FUNCTIONS
The table below briefly describes how each of the special functions available
to the user and to the Service Engineer can be used.
Function Activation of the function Starting the function Brief description / Comments
Keys Led(s) Keys Led(s)
Select regeneration
[S1 + S2]
S0 (On/Off)
LD1 + LD2
flashing
S1
LD1
flashing
(description on page 24 / chapter 6.14). Press S1:
Liv….[1L]……[2L]….[3L]…...[ 4L]……[ 5L]…. [ 6L ]…...[ 7L] .…[ 8L]……[ 9L]….…[10L]
°F… >8 ….. >14 ..…>20 ….. >30 ….. >40 ….. >50 ….. >60 ….. >70 ….. >80 ….... >90
°D… >4 …... >8 ..…. >11 ..... >17 ….. >22 ….. >28 ….. >33 ….. >39 ….. >45 ……. >50
Disactivate rinse-
aid
S0 (On/Off)
[S2 + S3]
LD1 + LD2+ LD3
flashing
S2
LD2
flashing
(description on page 22 / chapter 6.10)
Press S2 and press again: 1d = rinse-aid activated, 0d = not activated
USER (*)
Disactivate buzzer
S0 (On/Off)
[S2 + S3]
LD1 + LD2+ LD3
flashing
S3
LD3
flashing
(description on page 11 / capitolo 4.6.1)
Press S3 and press again: 1b = buzzer activated, 0b = not activated
Display of alarms
and components
diagnostics
[S1 + S3]
S0 (On/Off)
LD1 + LD2 + LD3
flashing
S1
LD1
flashing
(description on page 29 / capitolo 10.2).
Press button S1:
[i.0] [i.0] [i.0] [4 ] [ 5] [ 6] [ 7 ] [ 8] [ 9 ] [10]
AL 1
AL2
AL 3
ER
PS
EV
RR
PL
DD
MV
Cancel alarms
stored in memory
[S1 + S3]
S0 (On/Off)
LD1 + LD2 + LD3
flashing
S2
LD2
flashing
(description on page 30 / capitolo 10.3)
All the LEDs and digits flash for 30 sec.
Test cycle
[S1 + S3]
S0 (On/Off)
LD1 + LD2 + LD3
flashing
S3
LD3
flashing
(description on page 30 / capitolo 10.4)
The cycle starts automatically
Extra rinse
[S1 + S3]
S0 (On/Off)
LD1 + LD2 + LD3
flashing
[S1 + S2]
S1
LD1
flashing
(description on page 31 / capitolo 10.5.1)
Press S1 and press again: 1A = rinse activated 0A = not activated
SERVICE ENGINEERS
Disable buttons
[S1 + S3]
S0 (On/Off)
LD1 + LD2 + LD3
flashing
[S2 + S3]
S2
LD2
flashing
(description on page 31 / capitolo 10.5.2)
Press S2 and press again: 1P = pulse wash PW activated;
0P = continuous wash
Exit / Memorize
In order to memorize the functions or exit diagnostics mode, press key S0 to switch the appliance off. In most cases, memorization / exit take place automatically after 60 seconds (in
which case the appliance returns to pre-selection mode)
(*) To activate the functions available to the user, no cycles must be selected (i.e. the appliance must be in pre-selection mode).