26
Service Manual
Loosen the spring from the “motor arm”.
Loosen the belt (C) from the “motor arm”.
Turn the tension arm counter clockwise in the holes (D) to loosen it from the motor panel.
fig.7217A
Demount the motor by unscrewing the four screws.
Mount the new motor. Tighten the screws crosswise (1, 4, 2 and 3) with tightening torque 16.5 Nm ± 3.
In order to fasten the belt again, first loosen the four screws a bit.
fig.490377800