11.2.2 Removing the chain guard
Turn the machine off and take the key out
of the ignition.
Remove the two bolts (1) (M10 slw 17).
Remove the guard.
11.2.3 Disconnecting the battery
Disconnect the negative terminal (1) (black
M6 slw 10).
Disconnect the positive terminal (2) (red
M6 slw 10).
Caution:
First connect the positive terminal (2) (red M6, SW 10).
And then the negative terminal (1) (black M6, SW 10). Never disconnect the
battery for longer than 1 day.
11.2.4 Opening the Axelero
TM
chamber
Caution:
Make sure the Axelero
TM
has come to a standstill before opening the Axelero
TM
chamber. Turn the motor off and take the key out of the ignition.