Rated operating power 150 250 1200 W
NOTE:
The switch inside the NED-100D switching power needs to be switched
to the gear 115V when the external mains supply is 90~130VAC.
DANGER:
1. Please make sure that the robot is grounded correctly (electrical
connection to ground). Please establish the common grounding for all
equipments inside the system with bolts which are unused and
connected to the grounding symbols inside the control box. The
grounding conductor should have at least the rated current of the
highest current in the system.
2. Make sure that the input current of the control box is protected
with the residual current device (RCD) and the appropriate fuse.
3. The lockout and tagout should be implemented for all power
supplies when the robot needed to complete all services is installed
and set. The robot I/O should not be powered by other equipments
when the system is locked.
4. Please make sure that all cables are connected correctly before the
control box is powered on. Always use the original power cord.
5. The operation of switching the switch inside the NED-100D
switching power should be implemented before the box is not
connected with the power supply.