MES1000, MES2000 Ethernet Switches 111
console(config-cfm-md)#
Table 5.107 —CFM domain (MD) configuration mode commands
id { dns dns | name name |
id mac mac_address
number | id null }
name: (1..43) characters
dns: (1..43) characters
mac_address: H.H.H or
H:H:H:H:H:H or H-H-H-H-H-
H
number: (0-65535)
By default: id name
matches the domain name
Specify CFM domain (MD) identifier. Possible domain names:
- dns—dns name
- name—text string
- mac_address number—MAC address and domain numeric
identifier
- null—NULL identifier
service port { vlan-id
vlan_id | name name |
number number }
vlan: (1..4094)
vlan_id: (1..4094)
name: (1..45) characters
number: (0..65535)
Create CFM maintenance (MA) without VLAN association and
enter the maintenance configuration mode.
Remove CFM maintenance (MA).
service vlan vlan { vlan-id
vlan_id | name name |
number number
Create CFM maintenance (MA) associated with VLAN (with
'vlan' number) and enter the maintenance configuration
mode. Possible service names:
- vlan_id—VLAN number
- name—text string
- number—numeric identifier
no service vlan vlan_id }
Remove CFM maintenance (MA) associated with VLAN (with
'vlan' number).
mip auto-create [lower-
mep-only]
-/automatic creation is
disabled
Enable automatic creation of maintenance intermediate
points (MIP). Maintenance intermediate points (MIP) created
on all ports, where VLAN maintenance is defined.
Optional parameter 'lower-mep-only' allows to exclude ports,
where maintenance end point is created.
Restore the default value.
Maintenance configuration mode commands
Command line request in domain configuration mode appears as follows:
console(config-cfm-ma)#
Table 5.108 —CFM maintenance (MA) configuration mode commands
continuty-check interval
interval
interval: (1, 10, 100, 600)
seconds/1 second
Set the Continuty Check message sending interval.
no continuty-check interval
Set the downstream direction for the maintenance end point
(MEP).
Set the upstream direction for the maintenance end point
(MEP).
Add the maintenance end point (MEP) with 'id' identifier to
this maintenance.
This command performs MEP association with the
maintenance only. MEP is created in the interface
configuration mode.
Remove maintenance end point (MEP).
mip auto-create [ { lower-
mep-only | none } ]
-/The mode, configured for
domain with existing
maintenance, is used by
default
Enable automatic creation of maintenance intermediate
points (MIP). Maintenance intermediate points (MIP) created
on all ports, where VLAN maintenance is defined. Optional
parameters:
- lower-mep-only—allows to exclude ports, where
maintenance end point is created
- none—disable automatic creation of maintenance