64 MES1000, MES2000 Ethernet Switches
defined, all compatibilities are supported (Ethernet, port-
channel).
no negotiation
Disable autonegotiation of speed and duplex on the
configured interface.
flowcontrol mode
(on, off, auto)/off
Define the 'flowcontrol ' flow control mode (enable, disable or
autonegotiation). Flowcontrol autonegotiation works only
when negotiation mode is enabled on configured interface
(Ethernet, port-channel).
no flowcontrol
Disable flow control mode.
mdix mode
(on, auto)/auto
Enable the crossed cable utilization for the configured
interface (Ethernet).
no mdix
Disable the crossed cable utilization for the configured
interface (Ethernet).
back-pressure
-/disabled
Enable 'backpressure' function for the configured interface
(Ethernet).
no back-pressure
Disable 'backpressure' function for the configured interface.
load-average period
period: 5..300/15
Specify the period of load statistics collection for the interface.
no load-average
Set the default value.
Global configuration mode commands
Command line request in global configuration mode appears as follows:
console(config)#
Table 5.33 Ethernet and Port-Channel interface general configuration mode commands
Command
Value
Action
port jumbo-frame
-/denied
Enable processing of jumbo fames by the switch.
Maximum transmission unit (MTU) default value is
1500 bytes.
Configuration changes will take effect after the
switch is restarted.
Maximum transmission unit (MTU) value for port
jumbo-frame configuration is 10'200bytes.
no port jumbo-frame
Disable processing of jumbo fames by the switch.
errdisable recovery cause
{loopack-detection |
port-security |
dot1x-src-address |
acl-deny |
stp-bpdu-guard |
stp-loopback-guard }
-/denied
Enable automatic interface activation after its disconnection in
the following circumstances:
- loopback-detectionloopback-detection
- port-securitysecurity breach for port security
- dot1x-src-addressuser MAC authentication failed
- acl-denynon-compliance with access lists (ACL)
- stp-bpdu-guardBPDU Guard activation (unauthorized BPDU
packet transmission via the interface)
- stp-loopback-guardloopback detection
no errdisable recovery
cause { loopack-detection |
port-security |
dot1x-src-address |
acl-deny |
stp-bpdu-guard |
stp-loopback-guard }
Set the default value.
errdisable recovery
interval seconds
seconds: (30..86400}/300
seconds
Define the time period for automatic interface reactivation.
no errdisable recovery
interval
Set the default value.