EM TEST CNI 501 / CNI 503
Manual of operation V 3.32 26 / 41
7.
ANSI Coupling (option)
The option ANSI offers to change the coupling mode for surge tests between ANSI and IEC coupling
To change the coupling mode to ANSI, it is necessary to press the button ANSI / IEC.
Disable the ANSI/IEC button (LED = off) when using the iec.control software.
Coupling
Figure 7.1:
LED disabled: IEC coupling 2 L-L or L-N 10 L-PE, N-PE
Software iec.control switches automatically between IEC and
ANSII coupling.
LED enabled : ANSI coupling 2 all couplings
Software iec .control couples always with 2 as long the LED is
on and cannot switch between IEC and ANSI
REMARK: The LED indication works only with manual operation ANSI / IEC. During
remote control from UCS500N6B the LED will not be on. In each case the
coupling, indicated in the generator display is correct.
Without option ANSI No function of the ANSI / IEC button and LED (ANSI)