EasyManua.ls Logo

EM TEST RDS 200N - VDS 200 N100.4 Operating Elements; Overvoltage Protection VDS200 N100.4

Default Icon
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EM TEST VDS 200 Series
Manual for Operation V 5.19 13 / 57
2.4.
VDS 200N100.4 operating elements
The VDS 200N100.4 includes an internal overvoltage protection selectable by a switch at the rear side. The
protection levels are 20V, 30V, 40V and 60V. The overvoltage protection works as a crowbar, switches in a
few µs and discharges the storage capacitor bank and switches off the charging rectifier.
Front side
Rear side
1 Power output frontside
2 Mains plug 230V fused on F4 total 16A
1 Power output rear side
2 Fuse F4 for all mains output 16AT (6x32mm)
3 Mains 230V fused total 16A
4 Mains input 3 x 400 V ac
5 Fuse F1…F3 32A gG (10.3 x 38mm)
6 Main Switch
7 Overvoltage protection selector switch
2.4.1.
Overvoltage protection VDS200N100.4
The overvoltage protection switch selects the
following protection levels:
20.0V, 30.0V, 40.0V, 60.0V
The protection will switch off the output voltage
and discharge the internal dc-capacitor bank. The
protection is a hardware solution and independent
of the controller.

Table of Contents