Manual for Operation V 5.19 20 / 57
3.3.2.
ISO 16750-2 WD 03/2000-2
3.3.2.1.
Short voltage drop
This test is to simulate the effect of a classical fuse actuation in another circuit.
tr, tf = 10ms
Limits depends VDS voltage range
Input restrictions
0.0 V Vb + Va1 30.0V (60.0V)
0.0 V Vb + Va2 30.0V (60.0V)
Parameters:
Vb
0.0V
-
30.0V (60.0V)
Va1
- 30.0V (- 60.0V)
-
30.0V (60.0V)
Va2
- 30.0V (- 60.0V)
-
30.0V (60.0V)
t1
0.1s
-
99.9s
t2
0.1s
-
99.9s
t3
0.1s
-
99.9s
int
0.1s
-
99.9s
n
1
-
30,000 / endl.
tri
Auto / Manual
I
1A
-
30A (Imax)
3.3.2.2.
Slow decrease / increase
This test is to simulate a gradual discharge and recharge of the battery.
Parameters:
V1
0.0V
-
30.0V (60.0V)
V2
- 30.0V (- 60.0V)
-
30.0V (60.0V)
t1
0.1s
-
99.9s
t2
0.1s
-
9999.9s
I
1A
-
30A (Imax)
Remarks:
WD 03/2000-2 Voltage change rate = ( 3 0.1 ) V per minute
ISO 16750-2 Voltage change rate = ( 0.5 0.1 ) V per minute

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EM TEST VDS 200 Series and is the answer not in the manual?

EM TEST VDS 200 Series Specifications

General IconGeneral
BrandEM TEST
ModelVDS 200 Series
CategoryAmplifier
LanguageEnglish

Related product manuals