completely after 15 minutes. The hardware information guide for your system provides
details on all LEDs.
Verify DPE status
Ensure that the DPE is powered up correctly using the physical indicators on the
enclosure. The hardware information guide for your system provides more information on
all the LEDs.
Figure 9 DPE Front LEDs
A
B
SP
SP
Will Make the Array Unusable
Caution: Array Software on drives 0-3. Removing or relocating them
01
01
1
2
3
45
LEDs Location State/Color
SP Fault/status 1 Off
SP Unsafe to remove 2 Off
SP Power 3 On/Solid green
DPE Power 4 On/Solid blue
DPE Fault 5 Off
Procedure
1. Verify that the DPE Power LED located on the front is solid blue and the DPE Fault is off
as shown in Figure 9 on page 29.
2. Verify that the SP Power LEDs on both SP A and SP B are solid green and the SP Fault/
Status LEDs are off as shown in Figure 9 on page 29.
Note
If any fault LEDs are on, or if any power LEDs remain flashing after approximately 15
minutes of operation, contact your authorized service provider.
3. Ensure the power-up is complete before you continue with the next task.
Power up
Verify DPE status 29

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EMC2 EMC VNX Series and is the answer not in the manual?

EMC2 EMC VNX Series Specifications

General IconGeneral
BrandEMC2
ModelEMC VNX Series
CategoryStorage
LanguageEnglish

Related product manuals