October 2015
Service Instructions
127072E Rev. C
21
Section 4: Field Conversions
Field Conversions
Section 4: Field Conversions
4�1 Fail Mode Reversal (CW to CCW or CCW to CW)
4�1�1 Remove spring module per Section 5.3.
4�1�2 Remove hydraulic power module per Section 5.5.
4�1�3 Reinstall the spring module onto the opposite end of housing (1-10) as it was
previously located per Section 5.4.
4�1�4 Reinstall the override cylinder assembly into spring module per Section 5.2.
4�2 Convert Double-Acting Actuator to
Spring-Return with M11 Module
4�2�1 Remove blind end cap per steps 4.2.1.1 and 4.2.1.2.
4�2�1�1 Remove hex cap screws (5-20), with spring lockwashers (5-30), from blind
end cap (5-10).
4�2�1�2 Remove blind end cap (5-10) from end of housing (1-10).
4�2�2 If hydraulic power module needs to be relocated due to fail mode requirements
(fail counterclockwise) use Section 5.3 for removal and Section 5.4 for installation.
4�2�3 Install Powr Swivl module per Section 5.6.
4�2�4 Install the spring module onto the end of housing (1-10) per Section 5.4.
4�2�5 Install the override cylinder assembly into spring module per Section 5.2.

Table of Contents

Other manuals for Emerson Bettis G2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Bettis G2 Series and is the answer not in the manual?

Emerson Bettis G2 Series Specifications

General IconGeneral
BrandEmerson
ModelBettis G2 Series
CategoryController
LanguageEnglish

Related product manuals