33
Alarm "Hardware n°"
Section 5: Alarm "Hardware n°"
Hardware 8
No communication between the bus card and base card.
Turn off the power and check that the base card is equipped with the correct bus interface
card. Cycle power on the actuator and check the following parameters in the "RESTRICTED"
menu routines:
HW config: should be set to the "option" corresponding to the bus interface
present on the base card.
Bus protocol: should be set to "I24" or "I20" according to the relevant bus protocol
instruction manual.
Hardware 9
Reserved. Not used for XTE3000.
Hardware 10
Reserved. Not used for XTE3000.
Hardware 11
No communication between the bus (Profibus redundant card) and logic card. Turn off the
power and check that the base card is equipped with the correct bus interface card.
Cycle power on the actuator and check the following parameters in the "RESTRICTED"
menu routines:
HW config: should be set to the "option" corresponding to the bus interface
present on the base card.
Bus protocol: should be set to "I24" or "I20" according to the relevant bus protocol
instruction manual.
Hardware 12
No communication between the encoder and logic card.
Turn off the power and check the encoder cable; if damaged, it must be replaced.
Cycle power on the actuator to check if the problem is corrected.
If the problem is not corrected, replace the Encoder. Cycle power on the actuator to check if
the problem is resolved.
If the problem is still not corrected, replace the Logic Card. Cycle power on the actuator to
check if the problem is resolved.
Hardware 13
Encoder damaged or incorrectly configured.
Turn off the power and check the mechanical condition of the encoder. If damaged, it must
be replaced. Cycle power on the actuator to check if the problem is corrected.
If the problem still not corrected, replace the Logic Card. Cycle power on the actuator to
check if the problem is resolved.

Other manuals for Emerson Bettis XTE3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Bettis XTE3000 and is the answer not in the manual?

Emerson Bettis XTE3000 Specifications

General IconGeneral
BrandEmerson
ModelBettis XTE3000
CategoryController
LanguageEnglish

Related product manuals