1A-6 / GP Transmitters 2808B
2808-16B - 2
2 - 1- 1 - 1 - 0 - 1 - 0 Å Model Suffix
| | | | | | | | |
| | | | | | | | |
# A B C D E F G H Å Position
# GP TRANSMITTER W/FLUSH
DIAPHRAGM
E G INDICATION (* = 1, 2 or 3)
0 * None (with cover 396291-01-5)
0 4 None (with cover 396601-01-4)
1 *
Local Digital Indication (Linear)
A B INPUT RANGE
1 3 0-17 to 0-100 inH
2
O
1 4 0-50 to 0-300 inH
2
O
1 5 0-67 to 0-400 inH
2
O
2 0 0-4 to 0-25 psi
2 1 0-8 to 0-50 psi
2 2 0-17 to 0-100 psi
2 3 0-50 to 0-300 psi
2 4 0-83 to 0-500 psi
2 5 0-167 to 0-1000 psi
2 6 0-500 to 0-3000 psi
F MOUNTING FLANGE
0 Without Flange
1 3” Class 150 Flange
2 3” Class 300 Flange
3 4” Class 150 Flange
4 4” Class 300 Flange
C DIAPHRAGM & CONNECTOR
MATERIAL
1 316 Stainless Steel
E G CERTIFICATION (* =any selection)
* 1 UL/CUL (see Table Note 1)
* 2 CENELEC
0 4 UL/CUL (see Table Note 2)
D FILLING MATERIAL
1 DC200 Silicone Fluid
E G H WARNING PLATE
(* =any selection)
* * 0 None
0
1 1 Russian (Without Indication)
1
1 1 Russian (With Indication)
Table Note 1: (Class I, Div. 1, Groups C & D – Explosion Proof)
(Class I, Div. 2, Groups A, B, C, D)
Table Note 2: (Class I, Div. 1, Groups C & D – Intrinsically Safe)
(1-5 Vdc Output Only)
(Can ONLY be used with Intrinsically Safe TeleFlow and IStran Assembly)
NOTE
This table is only provided for product identity and not for ordering purpose.