Service Manual Damcos LPU: LPU Technical Data
SM 8000-100-01 Ed 04 February 2017
114
Hydraulic Specification
*) Only bulkhead mounted on LPU. Please note that min. time is calculated value. BRCF spring and value differ-
ence can change the actual time.
**) The Standard minimum closing time is listed without QCB and based on an ordinary tank design, except for
the BRCF 16000 which only operates with a pressure tank. In case of LPU-S equipped with Pipes to actuator and/or
Pressure Tank an extensively increased closing time should be expected, please ask for guidance’s.
***) BRCF 16000 should always be equipped with a Pressure tank.
Actuator type Oil displacement Min. operating time (sec.) open/close for LPU-D
ml 50 Hz 60 Hz
BRC 125* 26 1.6 1.3
BRC 250 50 3.0 2.5
BRC 500 102 6.1 5.1
BRC 1000 209 13 10
BRC 2000 400 24 20
BRC 4000 800 48 40
BRC 8000 1600 96 80
BRC 16000 3100 186 154
KC 65 21 1.35 1.1
KC 125 82 4.9 4.1
KC 250 428 25.6 21.2
KC 325 793 48 40
KC 400 1700 102 85
Actuator type Oil displacement
Min. operating time (sec.) open for LPU-S
Min. closing time**
50 Hz 60 Hz N/A
BRCF 125* 26 4 3 1
BRCF 250 50 8 6 2
BRCF 500 102 15 13 4
BRCF 1000 209 31 26 8
BRCF 2000 400 60 50 16
BRCF 4000 800 120 100 32
BRCF 8000 1600 240 200 64
BRCF 16000*** 3100 465 388 248
KF 65 21 1.2 1.1 1
KF/KFR 125 82 4.9 4.1 3
KF/KFR 250/150 265 15.9 13.2 10
KF/KFR 250 428 25.6 21.2 17