Operating speed
The operating duration can be calculated from the oil displacement of the actuator. The LPU can
deliver a flow, smoothly manually adjusted from 250 to 1000 ml/min at 50 Hz.
Example
A BRC 250 can be opened in:
minimum 50 ml / 1000 ml x 60 sec. = 3.0 sec.
maximum 50 ml / 250 ml x 60 sec. = 12.0 sec.
For adjustment please refer to instruction.
Electrical Specification
Motor is protected against overheating with internal bimetal switch.
Working pressure 135 bar
Relief valve cracking pressure 150 bar
Safety valve pressure 210 ± 40 bar
Max. running time Up to 10 minutes dependent on ambient temperature
Enclosure rating IP 68 (3 bar in 24 hours)
Test pressure 225 bar
Ambient temperature -5°C to 70°C ( -25°C to 70°C on request)
Tank volume / utility volume approx. 300 ml / 120 ml
Weight 18 kg
230 V AC 110 V AC
Power supply 230 V AC 50 or 60 Hz +10% / -20% 110 V AC 50 or 60 Hz ±10%
Starting current 4 A at 20°C 9 A
Running current max. 1.85A at 50 Hz / 2A at 60 Hz 3.5A
Running current at 20°C
(220 V 50 Hz)
1.2 A 2.5 A
The solenoid valve in:
LPU-S consumes approx.
LPU-D consumes approx.
12 W corresponding to 0.07A
9 W corresponding to 0.09 A
0.08 A
0.17 A

Table of Contents