Service Manual Damcos LPU: LPU Technical Data
SM 8000-100-01 Ed 04 February 2017
116
Materials
Cable Gland
Cable gland LPU-Ex and LPU-Ex-ia
For connection of cables cable gland M12x1.5 has to be rated for Ex-d up to minimum 2000 cm
3
enclosure volume for the actual gas class. Make sure that cable diameter fits cable glands and tighten
cable glands according to its specifications.
Cables
Shielded 230V supply cable is required for LPU-Ex and LPU-Ex-ia.
Electrical housing and tank Cast iron
Slides, etc. Steel
Screws, sign plate, rivets and bracket Stainless steel
Seals NBR/PTFE
Cable glands Brass/nickel
Hydraulic blocks Nodular cast iron
Application Thread No.
Min.
cable
ø
Max.
cable
ø
Screen IP Note
P-Net Control
230 V M20x1.5 2 8 15 no 68
P-NET M25x1.521316yes68
Power Control
230 V M25x1.5 1 12½ 20½ no 68
Alternative and additional options
External posi-
tion indicator
connection
M16x1.5 (1) 8 10 yes 68 LPU is delivered
with a plug in the
concerned thread
Reducer (thin-
ner cable)
M25/M20 (2) 68 f. cable gland
below
P-NET M20x1.5 (2) 8 11 yes 68 f. thinner P-NET
cable