2 Product certifications
Topics covered in this chapter:
Agency certifications
Government installation regulations
2.1 Agency certifications
The following are product agency certifications applicable to the Internal Display.
Agency certificationsTable 2-1:
Certification type Description
Electrical UL and CUL: Class I, Div. 1, Groups B, C & D
ATEX: Ex d IIC T6 Gb
IECEx: Ex d IIC T6 Gb
INMETRO (Brazil)
Environmental NEMA 4x (IP66)
Special conditions for safe use
Use a suitably certified and dimensioned cable entry device and/or plug. Install the
equipment so that the supply cable is protected from mechanical damage. Do not subject
the cable to tension or torque. If the cable is to be terminated within an explosive
atmosphere, then appropriate protection of the free end of the cable is necessary.
Year of construction
This information is contained within the serial number with the first four digits
representing the year and month in the YYMM format.
For European community
Install the Internal Display in accordance with the ATEX directive 94/9/EC.
2.2
Government installation regulations
Installation in USA
Install the Internal Display in accordance with the National Electrical Code (NEC) NFPA 70.
Installation in Canada
Install the Internal Display in accordance with the Canadian Electrical Code CSA 22.1.