5.6 Menu display functions
The meter displays various functions and messages during setup, programming and
operation. The main menu functions and messages in the order they appear in the menu
are listed in the table below.
Menu display functions Table 5-3:
Parameter Display Action/Setting
Setup SETUP Enter Setup menu
Input InPut Enter Input type selection menu
Active ActiV Set Active input type
NPN nPn Set NPN input type
PNP PnP Set PNP input type
Reed rEEd Set reed switch input type
Coil COIL Set coil input type
Isolated iSo Set isolated input type
Active low ActLO Set active input type with low threshold
NPN low nPnLO Set NPN input type with low threshold
PNP low PnPLO Set PNP input type with low threshold
K-Factor FActr Enter the K-Factor menu
K-Factor units FUn It Enter the K-Factor units
Pulses/gallon P/GAL Set K-factor in pulses per gallon
Pulses/liter P/L Set K-factor in pulses per liter
Pulses/imp gallon P/IGAL Set K-factor in pulses per imperial gallon
Pulses/meter
3
P/M3 Set K-factor in pulses per meter cubed
Pulses/barrel P/BBL Set K-factor in pulses per barrel
Pulses/bushel P/BUSH Set K-factor in pulses per bushel
Pulses/cubic yard P/ cuyD Set K-factor in pulses per cubic yard
Pulses/cubic feet P/cuFt Set K-factor in pulses per cubic foot
Pulses/cubic inch P/cuIn Set K-Factor in pulses per cubic inch
Pulses/liquid barrel P/LIBBL Set K-factor in pulses per liquid barrel
Pulses/beer barrels P/BBBL Set K-factor in pulses per beer barrel
Pulses/hectoliter P/HECtL Set K-factor in pulses per hectoliter
Pulses/custom unit P/CUST Set K-factor in a custom unit
K-Factor decimal
point
dEc.Pt Set the number of decimal points in the
K-factor
K-Factor value FActr Set the K-factor
Units UnitS Select standard units or custom unit/tag
Rate time base tbASE Enter the time base menu
Setup and programming
34 LTM Internal Display