4195KA, KB, KC, and KS Controllers
Instruction Manual
Form 5207
April 2007
1-7
Table 1-3. Process Sensor (Capsular Element) Pressure Ratings
CAPSULE
MATERIAL
CAPSULAR
STANDARD RANGES
SPAN
(1)
OPERATING RANGE
OPERATING
LIMIT
(2)
Min Max Min Max
N09902
Metric units
Positive pressure
0 to 150 mbar
0 to 400 mbar
0 to 0.6 bar
0.2 to 1 bar
0 to 1 bar
100 mbar
350 mbar
0.35 bar
0.4 bar
0.5 bar
160 mbar
700 mbar
0.7 bar
0.8 bar
1 bar
350 mbar
1 bar
1 bar
1 bar
1 bar
350 mbar
1 bar
1 bar
1.4 bar
1.4 bar
510 mbar
1.5 bar
1.5 bar
2 bar
2 bar
0 to 1.4 bar
0 to 1.6 bar
0.4 to 2 bar
0 to 2 bar
0.7 bar
1 bar
0.8 bar
1 bar
1.4 bar
2 bar
1.6 bar
2 bar
1 bar
1 bar
1 bar
1 bar
1.7 bar
2.4 bar
2 bar
2.4 bar
2.5 bar
3.5 bar
3 bar
3.5 bar
Vacuum
150 to 0 mbar
340 to 0 mbar
400 to 0 mbar
0.6 to 0 bar
1 to 0 bar
85 mbar
170 mbar
350 mbar
0.35 bar
0.5 bar
170 mbar
340 mbar
700 mbar
0.7 bar
1 bar
350 mbar
480 mbar
1 bar
1 bar
1 bar
350 mbar
480 mbar
1 bar
1 bar
1.4 bar
510 mbar
724 mbar
1.5 bar
1.5 bar
2 bar
Compound
50 to 100 mbar
175 to 175 mbar
150 to 250 mbar
0.2 to 0.4 bar
100 mbar
175 mbar
350 mbar
0.35 bar
160 mbar
350 mbar
700 mbar
0.7 bar
350 mbar
480 mbar
1 bar
1 bar
350 mbar
480 mbar
1 bar
1 bar
510 mbar
724 mbar
1.5 bar
1.5 bar
0.4 to 0.6 bar
0.6 to 0.8 bar
1 to 0.6 bar
1 to 1 bar
0.5 bar
0.7 bar
1 bar
1 bar
1 bar
1.4 bar
2 bar
2 bar
1 bar
1 bar
1 bar
1 bar
1.4 bar
1.7 bar
2.4 bar
2.4 bar
2 bar
2.5 bar
3.5 bar
3.5 bar
U.S. units
Positive pressure
0 to 60 inch wc
0 to 5 psig
0 to 10 psig
3 to 15 psig
0 to 15 psig
40 inch wc
2.5 psig
5 psig
6 psig
7.5 psig
60 inch wc
5 psig
10 psig
12 psig
15 psig
10 inch Hg
14 inch Hg
30 inch Hg
30 inch Hg
30 inch Hg
5 psig
7 psig
15 psig
20 psig
20 psig
7.5 psig
10.5 psig
22.5 psig
30 psig
30 psig
0 to 20 psig
6 to 30 psig
0 to 30 psig
10 psig
12 psig
15 psig
20 psig
24 psig
30 psig
30 inch Hg
30 inch Hg
30 inch Hg
25 psig
30 psig
35 psig
37.5 psig
45 psig
52.5 psig
Vacuum
5 to 0 inch Hg
10 to 0 inch Hg
20 to 0 inch Hg
30 to 0 inch Hg
2.5 inch Hg
5 inch Hg
10 inch Hg
15 inch Hg
5 inch Hg
10 inch Hg
20 inch Hg
30 inch Hg
10 inch Hg
14 inch Hg
30 inch Hg
30 inch Hg
5 psig
7 psig
15 psig
20 psig
7.5 psig
10.5 psig
22.5 psig
30 psig
Compound
30 to 30 inch wc
5 inch Hg to 2.5 psig
10 inch Hg to 5 psig
40 inch wc
2.5 psig
5 psig
60 inch wc
5 psig
10 psig
10 inch Hg
14 inch Hg
30 inch Hg
5 psig
7 psig
15 psig
7.5 psig
10.5 psig
22.5 psig
15 inch Hg to 7.5 psig
20 inch Hg to 10 psig
30 inch Hg to 15 psig
7.5 psig
10 psig
15 psig
15 psig
20 psig
30 psig
30 inch Hg
30 inch Hg
30 inch Hg
20 psig
25 psig
35 psig
30 psig
37.5 psig
52.5 psig
1. Minimum or maximum span, or any span in between, may be positioned anywhere within the operating range. For example, if a 0 to 350 mbar (0 to 5 psig) sensing element is used
and the minimum span of 1.75 mbar (2.5 psig) is set, the process indication can be calibrated to a range of 340 mbar to 203 mbar (10 inch Hg to 6 inch Hg), 0 to 172 mbar
(0 to 2.5 psig), 172 to 345 mbar (2.5 to 5 psig), 305 to 480 mbar (4.5 to 7 psig), or any value between minimum and maximum values of operating range.
2. Capsules with the travel stops set may be pressured to this value without permanent zero shift.