5 Power supply wiring
Depending on the power supply you plan to install, perform only one of the following
tasks:
Wiring the VDC power supply
Wiring the Power over Ethernet (PoE) power
5.1 Wiring the VDC power supply
You can install a user-supplied switch in the power supply line.
Important
For compliance with the Low Voltage Directive 2014/35/EU (European installations), verify
that the transmitter is located in close proximity to a switch.
Figure 5-1: Location of power supply wiring terminals and equipment ground
Procedure
1. Remove the housing cover and the display, where applicable.
2. Connect the power supply wires.
For DC power, connect to terminals VDC (+) and VDC (-).
3. Tighten the two screws of the power connector to hold the wire.
Installation Manual Power supply wiring
00825-0100-1600 March 2022
Installation Manual 25