A.5 Ordering information
Table A-4. Rosemount 3144P Temperature Transmitter Ordering Information
The starred offerings () represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
Model Product description
3144P Temperature transmitter
Housing style
Material Conduit entry size
D1 Field mount housing, dual-compartment housing Aluminum
1
/2–14-in. NPT
D2 Field mount housing, dual-compartment housing Aluminum M20 1.5 (CM20)
D3 Field mount housing, dual-compartment housing Aluminum PG 13.5 (PG11)
D4 Field mount housing, dual-compartment housing Aluminum JIS G
1
/2
D5 Field mount housing, dual-compartment housing Stainless steel
1
/2–14-in. NPT
D6 Field mount housing, dual-compartment housing Stainless steel M20 1.5 (CM20)
D7 Field mount housing, dual-compartment housing Stainless steel PG 13.5 (PG11)
D8 Field mount housing, dual-compartment housing Stainless steel JIS G
1
/2
Transmitter output
A 4—20 mA with digital signal based on HART Protocol
F FOUNDATION Fieldbus digital signal (includes three AI function block and backup link active scheduler)
Measurement configuration
1 Single-sensor input
2 Dual-sensor input
Product certificates
NA No Approval
E5 FM Explosion-proof, Dust Ignition-Proof, and Non-incendive approval
I5
(1)
FM Intrinsically Safe and Non-incendive (includes standard IS and FISCO for Fieldbus units)
K5
(1)
FM IS, Non-incendive and Explosion-proof combo (includes standard IS and FISCO for Fieldbus units)
KB
(1)
FM and CSA IS, Explosion-proof, and Non-incendive combo (includes standard IS and FISCO for FF units)
I6
(1)
CSA Intrinsically Safe/FISCO and Division 2 (includes standard IS and FISCO for Fieldbus units)
K6
(1)
CSA IS, FISCO Division 2 and Explosion-proof combo (includes standard IS, FISCO for Fieldbus units)
E1 ATEX Flameproof approval
N1 ATEX type n approval
I1
(1)
ATEX intrinsic safety approval (includes standard IS and FISCO for Fieldbus units)
K1
(1)
ATEX IS, Flameproof, Dust Ignition-Proof and type n combo (includes standard IS and FISCO for Fieldbus units)
ND ATEX Dust Ignition-Proof approval
KA
(1)
ATEX/CSA intrinsic safety, Explosion-proof combo (includes standard IS and FISCO for Fieldbus units)
E7 IECEx Flameproof approval
N7 IECEx Type 'n' approval

Table of Contents