Specifications and Reference Data
April 2017
Reference Manual
00809-0100-4021, Rev JA
Specifications and Reference Data
198
A.5.1 How to order Rosemount X-well Technology
Rosemount X-well Technology is for temperature monitoring applications and is not intended for control or safety
applications. It is available in the Rosemount 3144P Transmitter in a factory assembled direct mount configuration with a
Rosemount 0085 Pipe Clamp Sensor. It cannot be used in a remote mount configuration. Rosemount X-well Technology will
only work as specified with factory supplied and assembled Rosemount 0085 Sensor silver tipped single element sensor with
an 80 mm extension length. It will not work as specified if used with other sensors.
Rosemount X-well assemblies are available in most Rosemount 0085 Pipe Clamp Sensor diameter sizes.
Table A-5. Rosemount 3144P X-well Technology Option Code Requirements
Code Description
D1–D4
Aluminum field mount housing
PT
Temperature measurement assembled with Rosemount X-well Technology
A
4–20 mA with digital signal based on HART Protocol
XA
Sensor specified separately and assembled to transmitter
C1
Custom configuration of date, descriptor, message, and wireless parameters (requires Configuration Data Sheet with order)
HR7
Configured for HART Revision 7
Table A-6. Rosemount 0085 Pipe Clamp Sensor Option Code Requirements for Use with X-well Technology
Code Description
N
No connection head
3
Sensor connection
P1
Sensor type
J
Extension type
0080
Extension length
XA
Assemble sensor to specific temperature transmitter
Typical model number of the assembly: 3144P D 1A 1 NA M5 PT C1 HR7 XA
0085 N 3 P1 J 0080 C 0169 N XA