EasyManua.ls Logo

Emerson Rosemount OCX8800A - Specifications

Emerson Rosemount OCX8800A
328 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.3  Specifications
Note
All static performance characteristics are with operating variables constant.
Specifications subject to change without notice.
1.3.1  Net O
2
range
0-1 percent to 0-40 percent O
2
, fully field selectable
1.3.2  Combustibles
0-1000 ppm to 0-5 percent, fully field selectable
1.3.3  Accuracy
Oxygen
±0.75 percent of reading or 0.5 percent O
2
(whichever is greater)
Combustibles
±50 ppm
1.3.4 
System response to test gas
Oxygen
10 seconds T90
Combustibles
25 seconds T90
1.3.5 
Temperature limits
Process
32 to 2600 °F (0 to 1427 °C)
Sensors housing
-40 to 212 °F (-40 to 100 °C) ambient
Electronics housing
-40 to 149 °F (-40 to 65 °C), ambient
Description and specifications Manual
December 2022 00809-0500-4880
22 Emerson.com/Rosemount

Table of Contents