EDM01-36v10 DAG_9.2X2_Card_User_Guide - Configuring the DAG card
34 ©2010 - 2012 Endace Technology Ltd. Confidential - Version 10 - May 2012
Viewing the DAG card status
Interface Status
When you have configured the card according to your specific requirements you can view the interface
statistics to check the status of each of the links using:
dagconfig –dX –s
(Where X is the device number of the DAG card you want to configure).
For more information see dagconfig (page 33
).
There are multiple printout levels. The statistics displayed below are printout level 0.
• 1:
condition is present on the link.
• 0:
condition is not present on the link.
• -
: condition is not applicable.
Condition Definition
Indicates the port the status conditions apply to.
Card is locked to the incoming signal and can capture data.
The link is fully validated.
Loss of pointer. WAN mode only.
Indicates oof has been asserted for more than 3ms. WAN mode only.
Indicates loss of frame. 1GE mode only.
Auto negotiation process has completed, Only applicable when using copper transceivers.
1GE only.