Deltabar S FOUNDATION Fieldbus Identification
Endress+Hauser 11
3.2 Device designation
3.2.1 Nameplates
The MWP (maximum working pressure) is specified on the nameplate. This value refers to a
reference temperature of +20 °C (68°F) and may be applied to the device for an unlimited
time. Observe temperature dependency of the MWP. The pressure values permitted at higher
temperatures can be found in the standards EN 1092-1: 2001 Tab. 18 (With regard to their
stability-temperature property, the materials 1.4435 and 1.4404 are grouped together under
13EO in EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical.),
ASME B 16.5a – 1998 Tab. 2-2.2 F316, ASME B 16.5a – 1998 Tab. 2.3.8 N10276, JIS B
2220.
For PMD75, the MWP applies for the temperature ranges specified in the Technical
Information TI00382P in the "Ambient temperature range" and "Process temperature limits"
sections.
The test pressure corresponds to the over pressure limit (OPL) of the device = MWP x 1.5.
The Pressure Equipment Directive (2014/68/EU) uses the abbreviation "PS".
The abbreviation "PS" corresponds to the MWP (maximum working pressure) of the
measuring device.
3.2.2 Identifying the sensor type
See parameter "Sensor Meas.Type" in Operating Instruction BA00303P.
3.3 Scope of delivery
The scope of delivery comprises:
Deltabar S differential pressure transmitter
For PMD75 with side flanges made of AISI 316L or C22.8: additionally 2 vent valves, AISI
316L
PMD75 with side flanges made of AISI 316L or C22.8 and side vent: additionally 4 locking
screws, AISI 316L
For devices with the "HistoROM/M-DAT" option: CD-ROM with Endress+Hauser operating
program
Optional accessories
Documentation supplied:
Operating Instructions BA00301P and BA00303P are available via the Internet.
See: www.endress.com Download.
Brief Operating Instructions KA01024P
Fold-out brochure KA00252P
Final inspection report
Additional Safety Instructions with ATEX, IECEx and NEPSI devices
Optional: factory calibration form, test certificates