iTEMP TMT112 Technical data
Endress+Hauser 27
12.1.3 Type of input
Description Measuring range limits Min. span
Resistance
thermometer
(RTD)
Pt100
Pt500
Pt1000 acc. to IEC 751 (α = 0.00835)
Pt100 acc. to JIS C 1604-81 (α =
0.003916)
–200 to +850 °C (–328 to +1 562 °F)
–200 to +250 °C (–328 to +482 °F)
–200 to +250 °C (–328 to +482 °F)
–200 to +649 °C (–328 to +1 200 °F)
10 K (18 °F)
10 K (18 °F)
10 K (18 °F)
10 K (18 °F)
Ni100
Ni500
Ni1000 acc. to DIN 43760 (α =
0.006180)
–60 to +250 °C (–76 to +482 °F)
–60 to +150 °C (–76 to +302 °F)
–60 to +150 °C (–76 to +302 °F)
10 K (18 °F)
10 K (18 °F)
10 K (18 °F)
• Connection type: 2-, 3- or 4-wire connection
• Software compensation of cable resistance possible in the 2-wire system (0 to 30 Ω)
• Sensor cable resistance max. 40 Ω per cable
• Sensor current: ≤ 0.2 mA
Resistance
transmitter
Resistance Ω 10 to 400 Ω
10 to 2 000 Ω
10 Ω
100 Ω
Thermocouples
(TC)
B (PtRh30-PtRh6)
C (W5Re-W26Re)
1)
D (W3Re-W25Re)
1)
E (NiCr-CuNi)
J (Fe-CuNi)
K (NiCr-Ni)
L (Fe-CuNi)
2)
N (NiCrSi-NiSi)
R (PtRh13-Pt)
S (PtRh10-Pt)
T (Cu-CuNi)
U (Cu-CuNi)
2)
acc. to IEC 584 Part1
+40 to +1 820 °C (104 to +3 308 °F)
0 to +2 320 °C (+32 to +4 208 °F)
0 to +2 495 °C (+32 to +4 523 °F)
–270 to +1 000 °C (–454 to +1 832 °F)
–210 to +1 200 °C (–346 to +2 192 °F)
–270 to +1 372 °C (–454 to +2 501 °F)
–200 to +900 °C (–328 to +1 652 °F)
–270 to +1 300 °C (–454 to +2 372 °F)
–50 to +1 768 °C (–58 to +3 214 °F)
–50 to +1 768 °C (–58 to +3 214 °F)
–279 to +400 °C (–454 to +752 °F)
–200 to +600 °C (–328 to +1 112 °F)
500 K (900 °F)
500 K (900 °F)
500 K (900 °F)
50 K (90 °F)
50 K (90 °F)
50 K (90 °F)
50 K (90 °F)
50 K (90 °F)
500 K (900 °F)
500 K (900 °F)
50 K (90 °F)
50 K (90 °F)
• Cold junction internal (Pt100)
• Cold junction accuracy: ± 1 K
Voltage
transmitters
Millivolt transmitter –10 to 75 mV +5 mV
1) According to ASTM E988
2) According to DIN 43710