Power supply
An external power supply is required.
Various supply units can be ordered from Endress+Hauser.
2-wire, 4-20mA HART, passive
2-wire; 4-20mA HART
1)
"Approval"
2)
Terminal voltage U at the device Maximum load R, depending on the supply voltage U
0
at the
supply unit
Non-Ex
Ex nA
Ex ic
CSA GP
11.5 to 35 V
3)
4)
U
0
[V]
10
11.5
22.5
20 30 35
0
500
R
[ ]W
A0035511
Ex ia / IS 11.5 to 30 V
4)
Ex d / XP
Ex ic[ia]
Ex tD / DIP
13.5 to 30 V
4) 5)
R [ ]Ω
[V]U
0
10
13.5 24.5
20 30
0
500
A0034969
1) Feature 020 of the product structure: option A
2) Feature 010 of the product structure
3) For ambient temperatures T
a
≤ -30 °C (-22 °F) a minimum voltage of 14 V is required for the sartup of the device at the minimum error current
(3,6 mA). For ambient temperatures T
a
≥ 60 °C (140 °F) a minimum voltage of 12V is required for the sartup of the device at the minimum error
current (3,6 mA). The startup current can be parametrized. If the device is operated with a fixed current I ≥ 4,5 mA (HART multidrop mode), a
voltage of U ≥ 11,5 V is sufficient throughout the entire range of ambient temperatures.
4) If the Bluetooth modem is used, the minimum supply voltage increases by 2 V.
5) For ambient temperatures T
a
≤ -20 °C (-4 °F) a minimum voltage of 16 V is required for the startup of the device at the minimum error current
(3.6 mA).