Levelflex FMP53
76 Endress+Hauser
Pressure equipment with
allowable pressure
≤ 200 bar (2 900 psi)
Pressure instruments with a flange and threaded boss that do not have a pressurized housing do not
fall within the scope of the Pressure Equipment Directive, irrespective of the maximum allowable
pressure.
Reasons:
According to Article 2, point 5 of EU Directive 2014/68/EU, pressure accessories are defined as
"devices with an operational function and having pressure-bearing housings".
If a pressure instrument does not have a pressure-bearing housing (no identifiable pressure chamber
of its own), there is no pressure accessory present within the meaning of the Directive.
Radio approval
Satisfies "Part 15" of the FCC rules for an unintentional radiator. All probes meet the requirements
for a Class A digital device.
In addition, coax probes and all probes in metal vessels meet the requirements for a Class B digital
device.
Experience
FMP5x is the upgrade model of the FMP4x series.