Levelflex FMP53
38 Endress+Hauser
Separable probes
10
4.5 Nm
A0014166
The use of separable rod probes (Ø 8 mm) is advisable in confined mounting conditions (limited
distance to the ceiling).
Max. probe length 6 m (19.68 ft)
Max. lateral loading capacity 10 Nm
Probes can be separated several times, with the individual parts having the following lengths:
500 mm (20 in)
1 000 mm (40 in)
The connection points are sealed gap-free by an O-ring.
To avoid damage to the surface of the probe: use fitting pliers with a plastic surface to mount
the probe rod.