Levelflex FMP53
84 Endress+Hauser
Function
In addition to the verification parameters, the corresponding parameter values are also logged.
Existing measured variables, such as the echo amplitude, are used in the Foam detection and
Build-up detection wizards.
In the Levelflex FMP5x, the Foam detection and Build-up detection wizards cannot be used
together.
"Foam detection" wizard
The Heartbeat Monitoring module contains the Foam detection wizard.
This wizard is used to configure automatic foam detection, which detects foam on the product
surface on the basis of the reduced signal amplitude. Foam detection can be linked to a switch
output in order to control a sprinkler system, for example, which dissolves the foam.
This wizard can be used via FieldCare, DeviceCare or a DTM-based process control system.
"Build-up detection" wizard
The Heartbeat Monitoring module contains the Build-up detection wizard.
The wizard is used to configure automatic buildup detection, which detects the buildup of deposits
on the probe on the basis of the reduced signal amplitude.
This wizard can be used via FieldCare, DeviceCare or a DTM-based process control system.
Advantages
Early detection of changes (trends) to ensure plant availability and product quality.
Use of information for the proactive planning of measures (e.g. cleaning/maintenance).
Identification of undesirable process conditions as the basis to optimizing the facility and the
processes.
Automated control of measures to remove foam or buildup.
Detailed description