Levelflex M FMP41C with HART/4...20 mA Technical data
Endress + Hauser 81
10.1.7 Certificates and approvals
CE approval The measuring system meets the legal requirements of the EC-guidelines. Endress+Hauser confirms
the instrument passing the required tests by attaching the CE-mark.
Ex approval Correlation of safety instructions (XA) and certificates (ZE) to the instrument:
EHEDG approval Under development.
3A approval Under development.
Overspill protection WHG. See "Ordering structure" on → ä 8- (see ZE 256F/de).
Telecommunication Fulfils "Part 15" of the FCC regulations for an "Unintentional Radiator". All probes meet the
requirements for a "Class A Digital Device".
In addition to this, all probes in metallic tanks meet the requirements for a "Class B Digital Device".
Device Certificate Explosion protection Output
1)
Communication Housing
2)
KEMA 04
ATEX
XA WHG
FMP41C A non-ex B, G, H HART, 4...20 mA — — — —
D PROFIBUS PA — — — —
F FOUNDATION Fieldbus — — — —
F non-ex + WHG B, G, H HART, 4...20 mA — — — ZE256F/00/de
D PROFIBUS PA — — — ZE256F/00/de
1 ATEX II 1/2 G EEx ia IIC T6 B HART, 4...20 mA A 1129X XA261F-A —
D PROFIBUS PA A 1129X XA262F-A —
F FOUNDATION Fieldbus A 1129X XA262F-A —
B HART, 4...20 mA B 1129X XA268F-A —
D PROFIBUS PA B 1129X XA269F-A —
F FOUNDATION Fieldbus B 1129X XA269F-A —
B HART, 4...20 mA D 1129X XA272F-A —
D PROFIBUS PA D 1129X XA273F-A —
F FOUNDATION Fieldbus D 1129X XA273F-A —
3 ATEX II 1/2 G EEx em [ia] IIC T6 B HART, 4...20 mA C 1129X XA264F-A —
D PROFIBUS PA C 1129X XA264F-A —
F FOUNDATION Fieldbus C 1129X XA264F-A —
6 ATEX II 1/2 G EEx ia IIC T6 +
WHG
B HART, 4...20 mA A 1129X XA261F-A ZE256F/00/de
D PROFIBUS PA A 1129X XA262F-A ZE256F/00/de
B HART, 4...20 mA B 1129X XA268F-A ZE256F/00/de
D PROFIBUS PA B 1129X XA269F-A ZE256F/00/de
B HART, 4...20 mA D 1129X XA272F-A ZE256F/00/de
D PROFIBUS PA D 1129X XA273F-A ZE256F/00/de
7 ATEX II 1/2 G EEx d [ia] IIC T6 B, D HART, 4...20 mA
PROFIBUS PA
C 1129X XA263F-A —
1) assignment, see ordering information: 40 electronic insert/communication
2) assignment, see ordering information: 70 housing