M12 connector
Four-pole metal connector for mounting on transmitter.
For connecting to connection box or cable jack. Cable length 150 mm (5.91").
order no. 51502184
C-module accessories bag
capacitor for connecting the cable shielding to ground potential
Kit documentation SD108C/07/a3
order no. 71003097
Measuring cables CPK9 special measuring cable
For pH/ORP sensors with TOP68 plug-in head, for high-temperature and high-pressure applications, IP 68
Ordering acc. to product structure, see Technical Information (TI118C/07/en)
CPK12 special measuring cable
For pH/ORP glass electrodes and ISFET sensors with TOP68 plug-in head
Ordering acc. to product structure, see Technical Information (TI118C/07/en)
CYK71 measuring cable
non-terminated cable for the connection of sensors (e.g. conductivity sensors) or the extension of sensor
cables
Sold by the meter, order numbers:
non-Ex version, black: 50085333
Ex version, blue: 51506616
Extension cable CLK5
for inductive conductivity sensors, for extension via the VBM junction box, sold by the meter
order no.: 50085473
CYK10 Memosens data cable
For digital sensors with Memosens technology
Ordering according to product structure, see Technical Information (TI376C/07/en)
CYK81 measuring cable
non-terminated measuring cable for extension of sensor cables of e.g. Memosens, CUS31/CUS41
2 wires, twisted pair with shield and PVC-sheath (2x2x 0.5 mm
2
+ shield)
Sold by the meter, order no. 51502543
Sensors Glass electrodes
Orbisint CPS11/CPS11D
pH electrode for process applications, with PTFE diaphragm, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI028/C07/en)
Orbisint CPS12/CPS12D
ORP electrode for process applications, with PTFE diaphragm, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI367/C07/en)
Ceraliquid CPS41/CPS41D
pH electrode with ceramics diaphragm and liquid KCl electrolyte, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI079/C07/en)
Ceraliquid CPS42/CPS42D
ORP electrode with ceramics diaphragm and liquid KCl electrolyte, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI079/C07/en)
Ceragel CPS71/CPS71D
pH electrode with double chamber reference system and integrated bridge electrolyte,
Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI245/C07/en)
Ceragel CPS72/CPS72D
ORP electrode with double chamber reference system and integrated bridge electrolyte, Memosens
technology as option;
Ordering acc. to product structure, see Technical Information (TI374/C07/en)
Orbipore CPS91/CPS91D
pH electrode with open aperture for media with high dirt load, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI375C/07/en)