Liquiphant FTL64
22 Endress+Hauser
> 40 (1.57)
A0042335
 20 Installation example for a highly viscous liquid. Unit of measurement mm (in)
Avoid buildup
Use short installation sockets to ensure that the turning fork can project freely into the vessel.
Install preferably flush mount on vessels or in pipes.
Leave sufficient distance between the buildup expected on the tank wall and the tuning fork.
A0042345
 21 Installation examples for a highly viscous process medium
Take clearance into consideration
Allow sufficient space outside the tank for mounting, connection and settings involving the
electronic insert.
A0042340
 22 Take clearance into consideration