10 Operation
10.1 Display
10.1.1 Measuring mode
To display the measured values, press the soft key MEAS in the start screen, or during
operation press STAT under Measurement.
Press the navigator button to change the mode
There are various display modes:
Channel overview
The names of all the channels, the sensor type connected and the current main value are
displayed.
Main value of the selected channel
The name of the channel, the sensor type connected and the current main value are
displayed.
Main value and secondary value of the selected channel
The name of the channel, the connected sensor type and the current main value and
secondary value are displayed.
Temperature sensor 1 has a special function. The states of the compressor, ventilator
and heater are displayed (on/off).
All the measured values of all the inputs and outputs
The current main value and secondary value as well as all the raw values are displayed.
User-defined measuring screens
You configure what values you want to display. You can choose from all the measured
values of physical and "virtual" sensors (calculated using mathematical functions) and
output parameters.
In the first 3 modes, you can switch between channels by turning the navigator. In
addition to having an overview of all the channels, in the 4th mode you can also select
a value and press the navigator to see more details for the value. You can also find
your user-defined screens in this mode.
10.1.2 Device status
Icons on the display alert you to special device states.
Icon Location Description
Header bar Diagnostic message "Failure"
Header bar Diagnostic message "Maintenance request"
Header bar Diagnostic message "Check"
Header bar Diagnostic message "Out of specification"
Header bar Fieldbus or TCP/IP communication active
Header bar Hold active (for sensors)
At measured value Hold for the actuator (current output, limit switch etc.) is active
At measured value
1)
An offset has been added to the measured value
At measured value Measured value in "Bad" or "Alarm" state
At measured value Automatic temperature compensation active (for sensors)
At measured value Manual temperature compensation active (for sensors)
Header bar Simulation mode active or Memocheck SIM connected
At measured value The measured value is influenced by a simulated value