Flange connection to JIS B2220
Material: 1.4404 / 316L, PVDF
A0005599
Fitted electrodes Measuring electrodes and empty pipe detection electrodes
Standard with: 1.4435/316L, Alloy C-22, Tantalum, Platinum
DN 2 to 15 (1/12 to ½"): without empty pipe detection electrode
Process connections With O-ring:
Weld sockets (DIN EN ISO 1127, ODT/SMS)
Flange (EN (DIN), ANSI, JIS)
PVDF flange (EN (DIN), ANSI, JIS)
External pipe thread
Internal pipe thread
Hose connection
PVC adhesive fittings
With gasket seals:
Weld sockets DIN 11850, ODT/SMS
Clamps (ISO 2852, DIN 32676, L14 AM7)
Threaded joint DIN 11851, DIN 11864-1, ISO 2853, SMS 1145
Flange DIN 11864-2
Surface roughness (All data refer to parts in contact with medium)
Measuring tube lining with PFA: 0.4 μm (15 μin)
Electrodes
1.4435/316L, Alloy C-22, Tantalum, Platinum: 0.3 to 0.5 μm (12 to 20 μin)
Process connection made of stainless-steel: 0.8 μm (31 μin)
10K (PVDF)
20K (1.4404 /316L)
0
5
15
10
20
[bar][psi]
-60
-40
-20
020
40 60 80 100 120 140 160 180 [°C]
360 [°F]
0-40 100 200 300
100
200
300
25
0