Proline Promag 50H, 53H
8 Endress+Hauser
Electrical connection,
terminal assignment
Terminal assignment, Promag 50
Terminal assignment, Promag 53
The inputs and outputs on the communication board can be either permanently assigned or variable, depending
on the version ordered (see table). Replacements for modules which are defective or which have to be replaced
can be ordered as accessories.
Order variant Terminal No. (inputs/outputs)
20 (+) / 21 (–) 22 (+) / 23 (–) 24 (+) / 25 (–) 26 (+) / 27 (–)
50***-***********W Current output HART
50***-***********A Frequency output Current output HART
50***-***********D Status input Status output Frequency output Current output HART
50***-***********H PROFIBUS PA
50***-***********J +5 V (external
termination)
PROFIBUS DP
50***-***********S Frequency output,
Ex i, passive
Current output, Ex i,
passive, HART
50***-***********T Frequency output,
Ex i, passive
Current output, Ex i,
passive, HART
Ground terminal ä 7
Order variant Terminal No. (inputs/outputs)
20 (+) / 21 (–) 22 (+) / 23 (–) 24 (+) / 25 (–) 26 (+) / 27 (–)
Fixed communication boards (fixed assignment)
53***-***********A Frequency output Current output HART
53***-***********B Relay output 2 Relay output 1 Frequency output Current output HART
53***-***********F PROFIBUS PA, Ex i
53***-***********G FOUNDATION Fieldbus, Ex i
53***-***********H PROFIBUS PA
53***-***********J PROFIBUS DP
53***-***********K FOUNDATION Fieldbus
53***-***********Q Status input MODBUS RS485
53***-***********S Frequency output, Ex i Current output, Ex i,
passive, HART
53***-***********T Frequency output, Ex i Current output, Ex i,
passive, HART
Flexible communication boards
53***-***********C Relay output 2 Relay output 1 Frequency output Current output HART
53***-***********D Status input Relay output Frequency output Current output HART
53***-***********L Status input Relay output 2 Relay output 1 Current output HART
53***-***********M Status input Frequency output Frequency output Current output HART
53***-***********N Current output Frequency output Status input MODBUS RS485
53***-***********P Current output Frequency output Status input PROFIBUS DP
53***-***********V Relay output 2 Relay output 1 Status input PROFIBUS DP
53***-***********2 Relay output Current output Frequency output Current output HART
53***-***********4 Current input Relay output Frequency output Current output HART
53***-***********7 Relay output 2 Relay output 1 Status input MODBUS RS485
Ground terminal ä 7