Hardware settings Proline Promass 83
18 Endress+Hauser
PROFIBUS DP/PA
Modbus RS485
A0007552
Device address range: 0 to 126
Factory setting: 126
a. Miniature switches for device address
Example shown:
1+16+32 = device address 49
b. Miniature switches for the address mode (method
of addressing):
– OFF (factory setting) = software addressing via
local operation/operating program
– ON = hardware addressing via miniature
switches
c. Miniature switch not assigned.
A0007554
Device address range: 1 to 247
Factory setting: 247
a. Miniature switches for device address
Example shown:
1+16+32 = device address 49
b. Miniature switches for the address mode (method
of addressing):
– OFF (factory setting) = software addressing via
local operation/operating program
– ON = hardware addressing via miniature
switches
c. Miniature switch not assigned.