Proline Promass 83 Installation
Endress+Hauser
7
2.2 Installation conditions
For mechanical reasons, and in order to protect the piping, it is advisable to support heavy
sensors.
2.2.1 Dimensions
For the dimensions of the measuring device ï‚®ï€ see associated Technical Information on the
CD-ROM.
2.2.2 Mounting location
The following mounting locations are recommended:
• Upstream from assemblies such as valves, T-pieces, elbows, etc.
• On the pressure side of pumps (for high system pressure)
• At the lowest point in an ascending pipe (for high system pressure)
The following mounting locations should be avoided:
• At the highest point in a pipe (risk of air accumulating)
• In an open down pipe directly upstream from a free pipe outlet. For ways of using the
measuring device in down pipes, see the related Operating Instructions on the CD-ROM.