Proline Prosonic Flow B 200 HART Commissioning
Endress+Hauser 69
Configuring the pulse output
Navigation
"Setup" menu → Pulse/frequency/switch output
Structure of the wizard for the pulse output
Failure mode
End of wizard
Invert outp.sig.
Pulse
Volume flow
Assign pulse
Mass flow
Off
Pulse width
Value per pulse
Operating mode
Correct.vol.flow
Corr. vol.flow.
Corr CH4
volflow
Energy flow
Ref. comb. temp.
Cal.value calc.
A0019210-EN
 20 "Pulse/frequency/switch output" wizard in the "Setup" menu: "Operating mode" parameter"Pulse" option
Parameter overview with brief description
Parameter Prerequsite Description Selection / User
entry
Factory setting
Operating mode Define the output as a pulse,
frequency or switch output.
Pulse
Frequency
Switch
Pulse
Assign pulse output In the Operating mode
parameter the Pulse option is
selected.
Select process variable for
pulse output.
Off
Volume flow
Corrected volume
flow
Corrected methane
volume flow
*
Mass flow
Energy flow
*
Off