Proline Prosonic Flow B 200 HART Commissioning
Endress+Hauser 83
Parameter overview with brief description
Parameter Prerequsite Description Selection / User
entry
Factory setting
Assign process variable Select process variable for low
flow cut off.
Off
Volume flow
Corrected volume
flow
Corrected methane
volume flow
*
Mass flow
Energy flow
*
Flow velocity
Off
On value low flow cutoff One of the following options is
selected in the Assign process
variable parameter (→  83):
Volume flow
Corrected volume flow
Corrected methane volume
flow
*
Mass flow
Energy flow
*
Flow velocity
Enter on value for low flow cut
off.
Positive floating-
point number
Depends on country
and nominal
diameter
Off value low flow cutoff One of the following options is
selected in the Assign process
variable parameter (→  83):
Volume flow
Corrected volume flow
Corrected methane volume
flow
*
Mass flow
Energy flow
*
Flow velocity
Enter off value for low flow cut
off.
0 to 100.0 % 50 %