Proline Prosonic Flow P 500
Endress+Hauser 5
Measuring system
The measuring system consists of a transmitter and two or one sensor sets. The transmitter and
sensor sets are mounted in physically separate locations. They are interconnected by sensor cables.
The sensors function as sound generators and sound receivers. Depending on the application and
version, the sensors can be arranged for measurement via 1, 2, 3 or 4 traverses →  6.
The transmitter serves to control the sensor sets, to prepare, process and evaluate the measuring
signals, and to convert the signals to the desired output variable.
Transmitter
1
2
2
1 Transmitter with integrated ISEM
2 Sensor cable
Electronics and ISEM (intelligent sensor electronics module) in the transmitter housing.
Signal transmission: analog
Order code for "Integrated ISEM electronics", option B: transmitter
Sensor cables
Sensor cables can be ordered in various lengths →  73
Length: max. 30 m (90 ft)
Cable with a common shield and individual shielded cores
Ex Zone
Use in: Ex Zone 1 and 2; Class 1, Division 2 and Class 1, Division 1
Housing versions and materials
Transmitter housing
Aluminum, coated: aluminum, AlSi10Mg, coated
Cast, stainless: cast, stainless steel, 1.4409 (CF3M) corresponds to the properties of 316L
Window material: glass
Configuration
External operation via 4-line, backlit, graphic local display with touch control and guided menus
("Make-it-run" wizards) for application-specific commissioning.
Via service interface or WLAN connection:
Operating tools (e.g. FieldCare, DeviceCare)
Web server (access via Web browser)