1 Safety notes RMS 621
8 Endress+Hauser
1Safety notes
Safe operation of the energy manager can only be ensured if all hints and warnings in this installation
and operating manual are thorougly read and followed.
1.1 Correct use
The RMS 621 energy manager is a unit for monitoring energy and flows in water and steam
applications. It can be used in both heating and cooling systems. A large variety of different flow
sensors, temperature and pressure sensors can be connected to the unit. The energy manager
accepts the current/PFM/pulse or temperature signals from the individual sensors and from these
calculates the liquid and energy values:
–Volume and mass
Heat flow or energy
Heat energy differential
all using the international calculation standard IAPWS-IF 97.
The unit is classified as additional equipment and may not be used in a hazardous area.
The manufacturer cannot take responsibility for any damage caused by misuse of the unit. It is not
permitted to make any changes or reconstruction to the unit.
The energy manager has been designed for use in an industrial environment and may only be used
in an appropriately installed condition.
1.2 Installation, commissioning and operation
The unit is safely manufactured using state-of-the-art technology and complies with the respective
EU regulations. The unit could be dangerous if it is incorrectly installed or used.
Mechanical and electrical installation, commissioning and maintenance of the unit must only be
carried out by skilled and qualified personnel. The skilled personnel must have read and understood
these operating instructions and followed them carefully. Always make sure that the unit is correctly
connected following the electrical connection diagrams (see Chap. 4 "Electrical installation"). When
the unit covers are removed, all electrical contact protection is lost (danger of electrical shock). The
housing must only be opened by qualified skilled personnel.
1.3 Operational safety
Hazardous areas
The energy manager is classified as additional equipment and may not be installed in a hazardous
area.
Technical advancement
The manufacturer reserves the right to improve and update the technical details. For details of
improvements or additions to these instructions, please contact your local sales organisation.
1.4 Returns
Please contact both the transport agency and your supplier if any transport damage is discovered.