www.enersys.com
RECOMMENDED INSTALLATION EQUIPMENT AND SUPPLIES
Before working with the battery system, be sure that you have the proper protective clothing, safety equipment and
insulated tools as specified in the Safety, Storage, Operating and Maintenance Manual for the VRLA Modular Battery
Systems.
The following is a recommended list of equipment required for installation of a PowerSafe
®
DDm Battery System.
TABLE 1
EQUIPMENT REQUIRED CHECK IF ON HAND
Chalk Line
Torpedo Level (Plastic)
Torque Wrench (10-200 in-lbs) (SAE and Metric)
Torque Wrench (50-100 ft-lbs) (SAE and Metric)
Floor Anchors (User-supplied per battery system)
Floor Shims (User-supplied)
Drive Ratchet Wrench with Minimum 3” Extension (SAE and Metric)
Box Wrenches (SAE and Metric)
Screwdrivers
Wipes, Paper or Cloth
Stiff Bristle Nonmetallic Brush/Pad
Tape Measure (Nonmetallic)
Safety Equipment and Clothing
Small Paintbrush
Standard Allen Wrench Set
Be sure you have all the proper protective
clothing, safety tools and equipment on
hand before starting the installation.
8
Harmful if swallowed, inhaled, or in contact with skin. Acid causes severe skin burns and eye damage. May
damage fertility or the unborn child if ingested or inhaled. May cause harm to breast-fed children. May cause
cancer if ingested or inhaled. Causes skin irritation, serious eye damage. Contact with internal components
may cause irritation or severe burns. Causes damage to central nervous system, blood and kidneys through
prolonged or repeated exposure if ingested or inhaled. Irritating to eyes, respiratory system, and skin. May
form explosive air/gas mixture during charging. Extremely flammable gas (hydrogen). Explosive, fire, blast or
projection hazard.
Obtain special instructions before use. Do not handle until all safety precautions have been read and
understood. Wash thoroughly after handling. Do not eat drink or smoke when using this product. Avoid contact
during pregnancy/while nursing. Wear protective gloves/protective clothing, eye protection/face protection.
Use only outdoors or in a well-ventilated area. Avoid contact with internal acid. Do not breathe
dust/fume/gas/mist/vapors/spray. Keep away from heat/sparks/open flames/hot surfaces. No smoking.
IF SWALLOWED OR CONSUMED: rinse mouth. Do NOT induce vomiting. Call a poison center/doctor if you feel
unwell. IF ON CLOTHING OR SKIN (or hair): Remove/Take off immediately all contaminated clothing and wash
it before reuse. Rinse skin with water/shower. IF INHALED: Remove person to fresh air and keep comfortable
for breathing. Immediately call a POISON CENTER or doctor/physician. IF IN EYES: Rinse cautiously with water
for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If exposed/concerned,
or if you feel unwell seek medical attention/advice.
Store locked up, in a well-ventilated area, in accordance with local and national regulation.
Dispose of contents/container in accordance with local and national regulation. Keep out of reach of children.
EnerSys, 2366 Bernville Road, Reading, PA 19605, USA - Tel: +1 610-208-1991
Contains: Lead, Sulfuric Acid (Electrolyte), Lead Compounds.
DANGER
2201-8677

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EnerSys PowerSafe DDm Series and is the answer not in the manual?

EnerSys PowerSafe DDm Series Specifications

General IconGeneral
BrandEnerSys
ModelPowerSafe DDm Series
CategoryCamera Accessories
LanguageEnglish

Related product manuals