2021-0306-2507 47 00-02-1207
Kubota:
Pump Learning is available on engines equipped with the Denso ECU
. The display will automaticaly send pump learning
settings to the engine ECU.
Engine Control Mode
Description
Droop
Choosing Droop for Engine Control Mode is like a
mechanical engine's governor. The engine speed follows
“Accelerator Pedal Position [%] (0% - 100%)”. However,
when the load is increased, the engine speed drops like
a mechanical engine.
Isochronous
The engine speed follows “Target Engine Speed
[rpm]”.Even if the load is increased, the engine speed is
controlled to a constant speed. However, if the load
demand is bigger than the maximum power curve, the
engine cannot keep the engine speed in a cconstant
speed. The lowest engine speed and the highest engine
speed are specified by each engine model.
Engine Control Mode, the droop control mode is like a mechanical engine's governor
characteristics. The engine speed follows “Accelerator Pedal Position [%] (0% - 100%)”.
However, when the load is increased, the engine speed drops like a mechanical engine.
Isochronous: The engine speed follows “Target Engine Speed [rpm]”.Even if the load
is increased, the engine speed is controlled to a constant speed. However, if the load
demand is bigger than the maximum power curve, the engine cannot keep the engine
speed in a constant speed. The lowest engine speed and the highest engine speed are
specified by each engine model.