SQ-80 — Musician's Manual
2.3.1 All Sequence Dump Alert Packet
This message is transmitted by the sending SQ-80 to inform the receiving unit that it wishes to dump the entire
sequencer memory. Note: this message will not be recognized by an ESQ-1.
xxxxxxxx ESQ/SQ-80 System Exclusive Header
00100001 SQ-80 All Sequence Dump Alert code
0000LLLL
0000LLLL Low byte (in nybbles) of sequence size
0000hhhh
0000hhhh High byte (in nybbles) of sequence size
11110111 End of exclusive
2.3.2 One Sequence Dump Alert Packet
Transmitted by the sending SQ-80 to inform the receiving unit that it wishes to dump the currently selected single
sequence. This message can be received by an ESQ-1.
xxxxxxxx ESQ/SQ-80 System Exclusive Header
00000111 ESQ/SQ-80 One Sequence Dump Alert code
0000LLLL
0000LLLL Low byte (in nybbles) of sequence size
0000hhhh
0000hhhh High byte of sequence size
11110111 End of exclusive
2.3.3 Accept Message
Transmitted by the receiving SQ-80 to indicate that it will accept a sequence dump.
xxxxxxxx ESQ/SQ-80 System Exclusive Header
00000100 Sequence Accept code
11110111 End of exclusive
2.3.4 Reject Message
Transmitted by the receiving SQ-80 to indicate that it does not have sufficient memory to accept the dump from
the sending SQ-80.
xxxxxxxx ESQ/SQ-80 System Exclusive Header
00000101 Sequence Reject code
11110111 End of exclusive
2.3.5 No Free Sequence Message
Transmitted by the receiving SQ-80 in response to a One Sequence Dump Alert Packet (2.3.2) to indicate that it
does not have any empty sequence locations in which to place the incoming sequence.