EasyManua.ls Logo

Enterasys SecureStack B2 B2G124-24 - C2 RPS-SYS Redundant Power System; Stack Initialization Overview

Enterasys SecureStack B2 B2G124-24
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connecting AC and RPS-SYS Power
SecureStack B2 Installation Guide 3-17
C2RPS-SYS Redundant Power System
Ifyouareinstallinganoptionalredundantpowersystem(C2RPSSYS),refertothe
installationinstructionssuppliedwiththeSecureStackRPS.Theswitchisconnectedtoa
C2RPSPSMusingaC2RPSPSMCable.
Ifyouareinstallingtheswitchasastandaloneswitch,proceedtoConnectingtoConsole
Portfor
LocalManagementonpage 318.Ifyouareinstallingswitchesinastack
configuration,applypowertoeachswitchinorder,accordingtotheprocedureyouusein
ConfiguringSwitchesinaStackonpage 312.
Stack Initialization Overview
Whenyouinstallandconnectallthehighspeedstackingcablestotheswitchesinthe
stackbeforeapplyingpowertotheswitches,thefollowingoccurs:
•Theswitchthatwillmanage(Manager)thestackisautomaticallyestablishedwithall
otherswitchesestablishedasMemberswitchesinthestack.Whentheswitches
completetheirinitializations,oneoftheswitchesinthestackwillilluminateits
ManagerLED,indicatingthatitisthestackManager.TheManagerLEDoneach
Memberswitchwillbeoff.
•ThehierarchyoftheswitchesthatwillfunctionasbackupManagerisalsodetermined
incasethecurrentManager
malfunctions,ispowereddown,orisdisconnectedfrom
thestack.
•TheConsoleportoneachMemberswitchisdeactivated.OnlytheConsoleportonthe
ManagerswitchisactiveforoutofbandconfigurationtosettheIPaddress,
password,andotherconfigurationsettings.
OnceyouknowwhichswitchistheManager,
proceedtoConnectingtoConsolePortfor
LocalManagementonpage 318.
Caution: To prevent damaging the switch, DO NOTconnect a Power over
Ethernet-compliant Redundant Power System (C2RPS-POE) to the redundant power
supply connector. The switch is only compatible with the SecureStack C2RPS-SYS
redundant power supply system.
Precaución: No conecte una fuente de poder redundante (RPS) SecureStack C2 PoE
(C2RPS-POE) al cable de corriente. De lo contrario, el dispositivo puede dañarse.

Table of Contents

Related product manuals