USER GUIDE - v1.0
ID: 5928937
25 |
OCTO – 71521
Visit the ENTTEC website for
the latest version
Reset to factory defaults
Factory resetting the OCTO results in the following:
Resets the device name.
Enables DHCP.
Static IP Address reset (IP address = 10.(octet1).(octet2).(octet3) where the three bytes
are the last three bytes of the mac address in decimal)
Resets the gateway IP.
Netmask is set to 255.0.0.0
Restores standalone shows to factory default.
Direct mode is activated
Input protocol is set to Art-Net.
LED protocol is set as WS2812B.
Pixel color is set to RGB.
Both ports are set to output 4 universes. The start universe for output 1 is set as 0 and
output 2 as 4
Mapped pixels value is set to 680 pixels
DMX start address is set to 0
APA-102 global intensity set to maximum.
Using web interface
The reset to defaults command can be found under the Settings tab of the OCTO.
Once the command is pressed, a pop-up would appear as shown in the image below:
Using the reset button
The reset button restores the network configuration of the OCTO to factory defaults:
To reset to factory defaults, the following procedure must be performed:
Power off the unit
Press and hold the Reset button.
While holding the Reset button, power up the unit, and keep holding the button for 3
seconds.
Release the Reset button once the status led starts blinking red.