45
GB
Error display
In order to provide an immediate diagnosis for any errors that may occur, the following errors
can be determined via on-screen error codes.
Error code Error description
E100 –Temperature sensor fault (no signal)
E101 – Temperature sensor short circuit
E103 – Bench sensor (optional 2
nd
sensor) fault (no signal)
E104 - Bench temperature sensor (optional 2
nd
sensor) short circuit
E 111 Humidity sensor fault (no signal)
E211 – Overheating limiter fault (no signal or blown fuse)
E 510 Lack of water – refi ll period
E 511 Lack of water – refi ll period exceeded
For each error code the
warning icon on the screen starts to ash so that it is easy to
see that there is an error code.
To quit after notifi cation of a lack of water (error message E511) press the Mode button and
then immediately restart the device.
Other error options that are not displayed and their causes:
KScreen is blank – no background lighting
Check the main switch setting.
Check the mains connection! Each of the 3 phases L1, L2 and L3 must have 230V AC.
Check the fuses!
The temperature can not be set to over 70°C
Check whether the device is in Finnish mode. („P3=0“)
Cabin light malfunction:
Check the fuse on the main board
Fan malfunction:
Check the fuse on the main board
Both fuses are 500 mA T
F1
F2
X3
X5a
X2
X1
L1 L2 L3 N
N
N
U
S1
FAN
LIGHT
WM
L N L N
500 mA T
500 mA T